Lithium-iron-phosphate (LiFePO4 or LFP) is the safest of the mainstream li-ion battery types. The nominal voltage of a LFP cell is 3,2V (lead-acid: 2V/cell). A 12,8V LFP battery therefore consists of 4 cells connected in series; and a 25,6V battery consists of 8 cells connected in series.

  • With integrated cell balancing
  • Can be parallel and series connected 
  • Bluetooth app available to monitor cell voltage and temperature

Victron LifePO4 Battery 

  • 12.8V / 160Ah SmartVoltage: 12.8V
  • Ah: 160
  • Terminal Type: M10
  • Terminal Layout: RH+
  • Dimensions (inc terminals): H320 x W338 x D233mm
  • Weight: 33Kg
  • Battery Technology: Lithium
  • Warranty: 3 Years
Rugged
A LFP battery does not need to be fully charged. Service life even slightly improves in case of partial charge instead of a full charge. This is a major advantage of LFP compared to lead-acid. Other advantages are the wide operating temperature range, excellent cycling performance, low internal resistance and high efficiency (see below).  LFP is therefore the chemistry of choice for demanding applications.  A lead-acid battery will fail prematurely due to sulfation:
  • If it operates in deficit mode during long periods of time (i.e. if the battery is rarely, or never at all, fully charged).
  • If it is left partially charged or worse, fully discharged (yacht or mobile home during wintertime).

Efficient
In several applications (especially off-grid solar and/or wind), energy efficiency can be of crucial importance. The round-trip energy efficiency (discharge from 100% to 0% and back to 100% charged) of the average lead acid battery is 80%. The round-trip energy efficiency of a LFP battery is 92%.

The charge process of lead-acid batteries becomes particularly inefficient when the 80% state of charge has been reached, resulting in efficiencies of 50% or even less in solar systems where several days of reserve energy is required (battery operating in 70% to 100% charged state). In contrast, a LFP battery will still achieve 90% efficiency under shallow discharge conditions.

Size and weight
Saves up to 70% in space Saves up to 70% in weight

Expensive yet longer life
LFP batteries are expensive when compared to lead-acid. But in demanding applications, the high initial cost will be more than compensated by longer service life, superior reliability and excellent efficiency.

Bluetooth
With Bluetooth cell voltages, temperature and alarm status can be monitored. Very useful to localize a (potential) problem, such as cell imbalance.

BMS
Victron LFP batteries have integrated cell balancing and cell monitoring. Up to 5 batteries can be paralleled and up to four 12V batteries or two 24V batteries can be series connected, so that a 48V battery bank of up to 1500Ah can be assembled. The cell balancing/monitoring cables can be daisy-chained and must be connected to a Battery Management System (BMS).

Requires one of these BMS-es:

  • VE.Bus BMS – recommended for systems with Victron inverter/chargers.
  • smallBMS – recommended for use in small systems. 
  • Battery Management System BMS 12/200 – recommended for use in Automotive and Marine systems having DC-loads and Alternators.
  • Smart BMS CL 12/100 – recommended for use in Automotive and Marine systems having DC-loads and Alternators.
  • Lynx Smart BMS - recommended for use in large systems.

Model 

BAT512116610

Data Sheet

Available for local collection and fitting

Please note: These can only be ordered for COLLECTION IN STORE 

Payment & Security

Apple Pay Google Pay PayPal

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Estimate shipping

You may also like

Recently viewed